Keep food cold through an outage. Size for the compressor start, its cycling load and the hours you need covered.
For our example (Refrigerator, 30 W average), the smallest catalogued station that covers 24 hours even with 25% higher consumption is the Jackery Explorer 2000 v2 (2,042 Wh): ≈42.4 h in the typical case.
Calculate with my devicesA household refrigerator does not draw its running watts every minute. The compressor cycles on and off; room temperature, door opening and defrost heaters affect energy use. If you have an annual energy label, divide kWh/year by 365 to estimate daily kWh, but still check running watts and startup separately. A plug-in watt meter measured over 24–48 hours is a better input for your exact appliance.
The example device is already added. Edit its watts and hours, add anything else you need and compare stations, solar and budget.
The essentials for a quick backup plan.
Starting values are editable. Adjust watts, daily hours and quantities in your list.
Your plan runs on stored battery energy only.
Station weight limit: 30 kg. Other preferences remain active.
Scenario range: 35.4–50.9 h, with −20% / +25% device draw. 168+ means no interruption within the seven-day simulation.
EcoFlow DELTA 2 Max · 24 h target · 400 W solar configuration
Covers the conservative case
Covers the conservative case
Covers the conservative case
Solar columns are comparison scenarios. Turn on solar charging to include generation in your main plan.
Same devices, battery, starting charge and schedule. Cloudy uses 50% of the local monthly solar profile. Historical or estimated local profile; not a forecast. 168+ is the simulation limit.
Prices change often: confirm the final price, delivery and taxes in the store.
Only critical or important devices are selected. Add solar or a larger battery to extend this plan.
Suggestions preserve critical loads and do not change medical device settings.


Categories use the conservative runtime estimate and known item subtotals. Known cable and accessory costs are included; unpriced items remain pending. If an option wins more than one category, its labels are combined.
Save your scenario, share a link or print your backup checklist.
Battery only, full charge, 10% reserve and the planner’s default losses. Example load: 120 W running, 25% duty cycle, AC output.
| Power station | Capacity | Estimated runtime | days |
|---|---|---|---|
| EcoFlow RIVER 2 | 256 Wh | Exceeds limits | — |
| EcoFlow RIVER 3 Plus | 286 Wh | 5.9 h | ≈ 0.2 |
| Jackery Explorer 300 Plus | 288 Wh | Exceeds limits | — |
| Jackery Explorer 500 v2 | 512 Wh | 10.6 h | ≈ 0.4 |
| EcoFlow RIVER 2 Max | 512 Wh | 10.6 h | ≈ 0.4 |
| EcoFlow RIVER 2 Pro | 768 Wh | 16 h | ≈ 0.7 |
| BLUETTI AC70 | 768 Wh | Startup to verify | — |
| BLUETTI AC70P | 864 Wh | Startup to verify | — |
| Anker SOLIX C1000 Gen 2 | 1,024 Wh | 21.3 h | ≈ 0.9 |
| BLUETTI Elite 100 V2 | 1,024 Wh | Startup to verify | — |
| EcoFlow DELTA 2 | 1,024 Wh | 21.3 h | ≈ 0.9 |
| EcoFlow DELTA 3 Plus | 1,024 Wh | 21.3 h | ≈ 0.9 |
| EcoFlow DELTA 3 | 1,024 Wh | 21.3 h | ≈ 0.9 |
| Jackery Explorer 1000 v2 | 1,070 Wh | 22.2 h | ≈ 0.9 |
| Jackery Explorer 1000 Plus | 1,264 Wh | 26.3 h | ≈ 1.1 |
| Jackery Explorer 2000 v2 | 2,042 Wh | 42.4 h | ≈ 1.8 |
| Jackery Explorer 2000 Plus | 2,043 Wh | 42.5 h | ≈ 1.8 |
| EcoFlow DELTA 2 Max | 2,048 Wh | 42.6 h | ≈ 1.8 |
| BLUETTI AC200L | 2,048 Wh | Startup to verify | — |
| BLUETTI Elite 200 V2 | 2,074 Wh | Startup to verify | — |
| Jackery Explorer 3000 v2 | 3,072 Wh | 63.9 h | ≈ 2.7 |
| EcoFlow DELTA Pro 3 | 4,096 Wh | 85.1 h | ≈ 3.5 |
Planning estimates from the same engine as the calculator, not laboratory tests. Your device’s real consumption decides the result: measure it or read its label and edit it above. The model stops at 168 hours.
It depends on the fridge’s daily energy, not its running watts. Our example (120 W while the compressor runs, 25% duty cycle) averages about 30 W, or roughly 720 Wh per day before losses. With those assumptions a ~1 kWh station such as the EcoFlow DELTA 3 lasts about 21.3 h, and a ~2 kWh unit such as the DELTA 2 Max about 42.6 h. Edit the watts in the planner for your model.
Check three numbers separately: daily energy (label kWh/year ÷ 365), continuous running watts and compressor startup surge, which can be several times higher (the example assumes 900 W). The station’s AC output must exceed the running load and its documented surge must cover the start. Capacity then decides how many hours you get.
Yes, if the panel replaces during the day what the fridge uses in 24 hours. Winter and cloud cut production sharply, so the planner uses historical hourly PVGIS profiles for your city and month and shows typical-sun and cloudy scenarios. A historical average is not a forecast.