EcoFlow DELTA 2 MaxLiFePO₄ · 3,000 cycles
EcoFlow · Specs checked against the manufacturer · 2026-09-29

EcoFlow DELTA 2 Max

How long does it last? Battery-only estimates from the same 15-minute simulation as our planner (full battery, 10% reserve, no solar):

  • Refrigerator42.6 h
  • Laptop30.2 h
  • Wi-Fi router93.3 h
  • Television18 h
Capacity2,048 Wh
AC output2,400 W
Startup surge4,800 W
Weight23 kg
Solar input1,000 W
AC recharge81 min
949 €

Recorded price · 2026-09-29

Test it with your own devices ↓
BATTERY-ONLY EXAMPLES

How long can the EcoFlow DELTA 2 Max run everyday devices?

Each row uses one device continuously, a full battery, 10% reserve, 85% AC efficiency and 8 W of inverter consumption. No solar or expansion battery is included.

Device and assumed loadEstimated runtimeConsumption scenarios
Wi-Fi router10 W average93.3 h81.2 h – 105.9 h
Laptop45 W average30.2 h24.8 h – 36.6 h
Television80 W average18 h14.7 h – 22.1 h
Refrigerator30 W average · 120 W when running · 900 W startup assumption42.6 h35.4 h – 50.9 h
Freezer45 W average · 150 W when running · 1000 W startup assumption30.2 h24.8 h – 36.6 h

These are editable planning examples, not measured product tests. The range uses 25% higher and 20% lower device consumption; it is not a guarantee. The refrigerator assumes a 25% duty cycle and the freezer 30%. Check your actual wattage and motor startup. The model stops at 168 hours.

Calculation method and limitations
SOURCE-BASED

Specifications: EcoFlow DELTA 2 Max

Nominal capacity
2,048 Wh
Continuous AC output
2,400 W
Documented startup surge
4,800 W
Weight
23 kg
Solar input
1,000 W
Solar voltage window
11–60 V
Solar connector / adapter
XT60i
Modelled solar current limit
15 A
Claimed battery cycles
3,000
Rated AC charge time
81 min
Claimed UPS / EPS switching
30 ms
Modelled expansion battery
+ 2,048 Wh
Battery chemistry
LiFePO₄
Regional output versions
EU 230 V / 50 Hz · US 120 V / 60 Hz

Regional mains voltage requires the corresponding regional product. Solar voltage/current limits can apply per port; check the exact manual. Modelled DC/USB budgets are conservative planning bounds, not a full protocol compatibility test.

YOUR OWN SCENARIO

Test the EcoFlow DELTA 2 Max with your devices

Pick what you need to keep running, set the hours and add solar if you have it. The station stays selected; switch it any time to compare.

Configuration mode

The essentials for a quick backup plan.

Your backup setup

01 / THE ESSENTIALS

Select your devices

Tap to add or remove

Starting values are editable. Adjust watts, daily hours and quantities in your list.

Devices to keep powered3

DEVICEWATTSH / DAY
Daily energy 1,230 WhStartup peak 955 W

Let the sun do some work

Your plan runs on stored battery energy only.

Your power station

Your power outlook

24 H SCENARIO
26.4hours until first interruption
SCENARIO ESTIMATEDraw −20% / +25%

Scenario range: 21.6–30.1 h, with −20% / +25% device draw. 168+ means no interruption within the seven-day simulation.

Covers your selected scenario in the typical simulation
0%25%50%75%100%0 h6 h12 h18 h24 h
Battery levelSolar hoursReserve 10%
Total capacity2,048 Wh
Solar accepted0 Wh
Battery at 24 h20 %

One system. Three scenarios.

EcoFlow DELTA 2 Max · 24 h target · 400 W solar configuration

No solar

26.4 hUntil first interruption
Conservative
21.6 h
Battery at target
20%

Typical case only

Typical sun

140.7 hUntil first interruption
Conservative
66.9 h
Battery at target
67%

Covers the conservative case

Cloudy · 50%

46.2 hUntil first interruption
Conservative
35.6 h
Battery at target
54%

Covers the conservative case

Solar columns are comparison scenarios. Turn on solar charging to include generation in your main plan.

Same devices, battery, starting charge and schedule. Cloudy uses 50% of the local monthly solar profile. Historical or estimated local profile; not a forecast. 168+ is the simulation limit.

Make your power go further

Only critical or important devices are selected. Add solar or a larger battery to extend this plan.

Suggestions preserve critical loads and do not change medical device settings.

COMPARE THE POSSIBILITIES

Different ways to keep going

1 setups fit your scenario and known budget

Categories use the conservative runtime estimate and known item subtotals. Known cable and accessory costs are included; unpriced items remain pending. If an option wins more than one category, its labels are combined.

Keep your plan within reach

Save your scenario, share a link or print your backup checklist.

Transparent by designEvery estimate has a source or an explicit assumption.
Explore our methodologyBrowse all 22 stations