POWERPLAN GUIDE

Watts vs watt-hours: convert W to Wh and kWh

Use the W to Wh calculator with hours or minutes. Learn the formulas for Wh and kWh, then account for battery losses and output power.

01

Convert watts to Wh and kWh

Energy in Wh = operating watts × hours. Divide Wh by 1,000 to obtain kWh. For minutes, divide the time by 60 first: 1,200 W for 10 minutes uses 200 Wh, or 0.2 kWh, at the appliance. The calculator below performs these conversions; the full planner adds battery losses and schedules.

02

Power is the speed; energy is the amount

A 100 W device running for 5 hours uses 500 Wh at its input. A nominal 500 Wh station will deliver less after conversion losses, its own consumption and any reserve.

03

Nameplates are not average consumption

A power supply rated 65 W can serve a device drawing much less. Refrigeration cycles on and off. For better runtime inputs, measure energy over a representative day and keep startup power separate.

04

Use a realistic small-load example

A 10 W router plus an 8 W inverter overhead uses 18 W of battery-side load before other conversion assumptions. Low loads make the inverter overhead especially important. That overhead varies by model and settings.

TRY YOUR OWN NUMBERS

Watts to watt-hours calculator

Multiply operating power by time to calculate the energy used by a device. Choose minutes for a short use, such as a kettle or coffee maker.

500 Wh0.5 kWh100 W × 5 h = 500 Wh

This is device input energy, not the required battery capacity. Add conversion losses, inverter consumption, reserve and startup checks in the full planner. For a cycling device, use measured average draw over the chosen period.

FROM THEORY TO NUMBERS

The same energy, very different output needs

Each of these illustrative devices uses 200 Wh. The battery energy is the same, but their required output power is not.

LoadTime usedEnergy
20 W light10 hours200 Wh
100 W device2 hours200 Wh
1,200 W appliance10 minutes200 Wh

The 1,200 W appliance needs an inverter that can supply at least its running load, even though it uses no more energy in this example. A useful first estimate is runtime = usable battery Wh ÷ battery-side watts. Schedules, solar and inverter overhead require the fuller simulation.

Before choosing your setup

  • Compare capacity in Wh and continuous output in W as separate specifications.
  • Convert minutes to hours before multiplying: 10 minutes = 1/6 hour.
  • Add conversion losses and the battery reserve before estimating runtime.

Common questions

Are mAh and Wh interchangeable?

No. Converting charge to energy also requires the voltage: Wh = Ah × V. A mAh claim without its reference voltage is not a reliable way to compare stations.

Does a larger battery mean more output power?

Not necessarily. Expansion may increase energy storage without changing the station’s inverter or port ratings. Check the manufacturer’s specifications for the exact combination.

This guide explains electrical planning for portable plug-in devices. Verify your exact manufacturer manuals and operating conditions.

Sources & calculation method

Virginia Cooperative Extension · estimating appliance energyPowerPlan · methodology and model assumptionsEuropean Commission JRC · PVGIS