No solar
30.2 hUntil first interruption- Conservative
- 24.8 h
- Battery at target
- 29%
Covers the conservative case
Check compressor startup, daily cycling consumption and storage conditions before choosing backup capacity.
For our example (Freezer, 45 W average), the smallest catalogued station that covers 24 hours even with 25% higher consumption is the Jackery Explorer 2000 v2 (2,042 Wh): ≈30.2 h in the typical case.
Calculate with my devicesUse the freezer’s nameplate and a measured energy total if available. Deep-freeze temperature, ambient heat and lid opening all change its duty cycle. A station may have sufficient battery capacity but still fail the motor startup test. The planner checks AC output and a documented surge rating separately. If that rating is not verified, it asks for a manual check rather than substituting a power-lifting mode.
The example device is already added. Edit its watts and hours, add anything else you need and compare stations, solar and budget.
The essentials for a quick backup plan.
Starting values are editable. Adjust watts, daily hours and quantities in your list.
Your plan runs on stored battery energy only.
Station weight limit: 30 kg. Other preferences remain active.
Scenario range: 24.8–36.6 h, with −20% / +25% device draw. 168+ means no interruption within the seven-day simulation.
EcoFlow DELTA 2 Max · 24 h target · 400 W solar configuration
Covers the conservative case
Covers the conservative case
Covers the conservative case
Solar columns are comparison scenarios. Turn on solar charging to include generation in your main plan.
Same devices, battery, starting charge and schedule. Cloudy uses 50% of the local monthly solar profile. Historical or estimated local profile; not a forecast. 168+ is the simulation limit.
Prices change often: confirm the final price, delivery and taxes in the store.
Only critical or important devices are selected. Add solar or a larger battery to extend this plan.
Suggestions preserve critical loads and do not change medical device settings.


Categories use the conservative runtime estimate and known item subtotals. Known cable and accessory costs are included; unpriced items remain pending. If an option wins more than one category, its labels are combined.
Save your scenario, share a link or print your backup checklist.
Battery only, full charge, 10% reserve and the planner’s default losses. Example load: 150 W running, 30% duty cycle, AC output.
| Power station | Capacity | Estimated runtime | days |
|---|---|---|---|
| EcoFlow RIVER 2 | 256 Wh | Exceeds limits | — |
| EcoFlow RIVER 3 Plus | 286 Wh | 4.2 h | ≈ 0.2 |
| Jackery Explorer 300 Plus | 288 Wh | Exceeds limits | — |
| Jackery Explorer 500 v2 | 512 Wh | 7.6 h | ≈ 0.3 |
| EcoFlow RIVER 2 Max | 512 Wh | 7.6 h | ≈ 0.3 |
| EcoFlow RIVER 2 Pro | 768 Wh | 11.3 h | ≈ 0.5 |
| BLUETTI AC70 | 768 Wh | Startup to verify | — |
| BLUETTI AC70P | 864 Wh | Startup to verify | — |
| Anker SOLIX C1000 Gen 2 | 1,024 Wh | 15.1 h | ≈ 0.6 |
| BLUETTI Elite 100 V2 | 1,024 Wh | Startup to verify | — |
| EcoFlow DELTA 2 | 1,024 Wh | 15.1 h | ≈ 0.6 |
| EcoFlow DELTA 3 Plus | 1,024 Wh | 15.1 h | ≈ 0.6 |
| EcoFlow DELTA 3 | 1,024 Wh | 15.1 h | ≈ 0.6 |
| Jackery Explorer 1000 v2 | 1,070 Wh | 15.8 h | ≈ 0.7 |
| Jackery Explorer 1000 Plus | 1,264 Wh | 18.7 h | ≈ 0.8 |
| Jackery Explorer 2000 v2 | 2,042 Wh | 30.2 h | ≈ 1.3 |
| Jackery Explorer 2000 Plus | 2,043 Wh | 30.2 h | ≈ 1.3 |
| EcoFlow DELTA 2 Max | 2,048 Wh | 30.2 h | ≈ 1.3 |
| BLUETTI AC200L | 2,048 Wh | Startup to verify | — |
| BLUETTI Elite 200 V2 | 2,074 Wh | Startup to verify | — |
| Jackery Explorer 3000 v2 | 3,072 Wh | 45.4 h | ≈ 1.9 |
| EcoFlow DELTA Pro 3 | 4,096 Wh | 60.5 h | ≈ 2.5 |
Planning estimates from the same engine as the calculator, not laboratory tests. Your device’s real consumption decides the result: measure it or read its label and edit it above. The model stops at 168 hours.
Our example freezer (150 W running, 30% duty) averages about 45 W, roughly 1,080 Wh per day before losses. With those assumptions a ~1 kWh station such as the DELTA 3 lasts about 15.1 h, and a ~2 kWh unit such as the DELTA 2 Max about 30.2 h.
Because capacity (Wh) and power (W) are separate limits. The compressor demands a short surge that can be several times its running draw. If the station’s documented surge does not cover it, it trips at startup even with a full battery.
Open it as little as possible, keep it full and in a cool spot. Every opening and warm room increases compressor cycling. If you own a plug-in watt meter, measure 24–48 hours and enter your real figure in the planner.