PLAN FOR YOUR ESSENTIALS

Power station for a freezer

Check compressor startup, daily cycling consumption and storage conditions before choosing backup capacity.

QUICK ANSWER

For our example (Freezer, 45 W average), the smallest catalogued station that covers 24 hours even with 25% higher consumption is the Jackery Explorer 2000 v2 (2,042 Wh): ≈30.2 h in the typical case.

Calculate with my devices

A short compressor start can exceed the steady running load many times.

Use the freezer’s nameplate and a measured energy total if available. Deep-freeze temperature, ambient heat and lid opening all change its duty cycle. A station may have sufficient battery capacity but still fail the motor startup test. The planner checks AC output and a documented surge rating separately. If that rating is not verified, it asks for a manual check rather than substituting a power-lifting mode.

YOUR OWN NUMBERS

Calculate your setup

The example device is already added. Edit its watts and hours, add anything else you need and compare stations, solar and budget.

Configuration mode

The essentials for a quick backup plan.

Your backup setup

01 / THE ESSENTIALS

Select your devices

Tap to add or remove

Starting values are editable. Adjust watts, daily hours and quantities in your list.

Devices to keep powered1

DEVICEWATTSH / DAY
Daily energy 1,080 WhStartup peak 1,000 W

Let the sun do some work

Your plan runs on stored battery energy only.

Find your fit

Station weight limit: 30 kg. Other preferences remain active.

Your power outlook

24 H SCENARIO
30.2hours until first interruption
SCENARIO ESTIMATEDraw −20% / +25%

Scenario range: 24.8–36.6 h, with −20% / +25% device draw. 168+ means no interruption within the seven-day simulation.

Covers your selected scenario in the typical simulation
0%25%50%75%100%0 h6 h12 h18 h24 h
Battery levelSolar hoursReserve 10%
Total capacity2,048 Wh
Solar accepted0 Wh
Battery at 24 h29 %

One system. Three scenarios.

EcoFlow DELTA 2 Max · 24 h target · 400 W solar configuration

No solar

30.2 hUntil first interruption
Conservative
24.8 h
Battery at target
29%

Covers the conservative case

Typical sun

168+ hUntil first interruption
Conservative
90.7 h
Battery at target
63%

Covers the conservative case

Cloudy · 50%

62.0 hUntil first interruption
Conservative
42.7 h
Battery at target
58%

Covers the conservative case

Solar columns are comparison scenarios. Turn on solar charging to include generation in your main plan.

Same devices, battery, starting charge and schedule. Cloudy uses 50% of the local monthly solar profile. Historical or estimated local profile; not a forecast. 168+ is the simulation limit.

Make your power go further

Only critical or important devices are selected. Add solar or a larger battery to extend this plan.

Suggestions preserve critical loads and do not change medical device settings.

COMPARE THE POSSIBILITIES

Different ways to keep going

5 setups fit your scenario and known budget
Premium
  • Premium: More runtime or battery reserve, within your budget and weight limits.
Covers the scenario
Jackery Explorer 3000 v2
Jackery

Explorer 3000 v2

1699 €Known item subtotal
45.4 h 27 kg 3,072 Wh

Categories use the conservative runtime estimate and known item subtotals. Known cable and accessory costs are included; unpriced items remain pending. If an option wins more than one category, its labels are combined.

Keep your plan within reach

Save your scenario, share a link or print your backup checklist.

Transparent by designEvery estimate has a source or an explicit assumption.
Explore our methodologyBrowse all 22 stations
ALL STATIONS, SAME DEVICE

How long each power station runs it: Freezer

Battery only, full charge, 10% reserve and the planner’s default losses. Example load: 150 W running, 30% duty cycle, AC output.

Power stationCapacityEstimated runtimedays
EcoFlow RIVER 2256 WhExceeds limits—
EcoFlow RIVER 3 Plus286 Wh4.2 h≈ 0.2
Jackery Explorer 300 Plus288 WhExceeds limits—
Jackery Explorer 500 v2512 Wh7.6 h≈ 0.3
EcoFlow RIVER 2 Max512 Wh7.6 h≈ 0.3
EcoFlow RIVER 2 Pro768 Wh11.3 h≈ 0.5
BLUETTI AC70768 WhStartup to verify—
BLUETTI AC70P864 WhStartup to verify—
Anker SOLIX C1000 Gen 21,024 Wh15.1 h≈ 0.6
BLUETTI Elite 100 V21,024 WhStartup to verify—
EcoFlow DELTA 21,024 Wh15.1 h≈ 0.6
EcoFlow DELTA 3 Plus1,024 Wh15.1 h≈ 0.6
EcoFlow DELTA 31,024 Wh15.1 h≈ 0.6
Jackery Explorer 1000 v21,070 Wh15.8 h≈ 0.7
Jackery Explorer 1000 Plus1,264 Wh18.7 h≈ 0.8
Jackery Explorer 2000 v22,042 Wh30.2 h≈ 1.3
Jackery Explorer 2000 Plus2,043 Wh30.2 h≈ 1.3
EcoFlow DELTA 2 Max2,048 Wh30.2 h≈ 1.3
BLUETTI AC200L2,048 WhStartup to verify—
BLUETTI Elite 200 V22,074 WhStartup to verify—
Jackery Explorer 3000 v23,072 Wh45.4 h≈ 1.9
EcoFlow DELTA Pro 34,096 Wh60.5 h≈ 2.5

Planning estimates from the same engine as the calculator, not laboratory tests. Your device’s real consumption decides the result: measure it or read its label and edit it above. The model stops at 168 hours.

COMMON QUESTIONS

What people ask before buying

How long will a power station run a freezer?

Our example freezer (150 W running, 30% duty) averages about 45 W, roughly 1,080 Wh per day before losses. With those assumptions a ~1 kWh station such as the DELTA 3 lasts about 15.1 h, and a ~2 kWh unit such as the DELTA 2 Max about 30.2 h.

Why can a station have plenty of battery but fail to start a freezer?

Because capacity (Wh) and power (W) are separate limits. The compressor demands a short surge that can be several times its running draw. If the station’s documented surge does not cover it, it trips at startup even with a full battery.

How do I make a freezer last longer in an outage?

Open it as little as possible, keep it full and in a cool spot. Every opening and warm room increases compressor cycling. If you own a plug-in watt meter, measure 24–48 hours and enter your real figure in the planner.